A Mitsubishi Canter came in with the air conditioning not working at all.
Aaron, who handles our AC work, put the gauges on and found no gas in the system whatsoever. As he vacuumed it down to test it, the machine just kept sucking air and the gauges wouldn’t hold. That told us it was leaking somewhere. We connected our nitrogen bottle to track down where, and found the first leak. Then the next.
Eight leaks later, we’d found that every O-ring on the high side of the system had failed. O-rings are the small rubber seals at each pipe and joiner that keep the gas in. We replaced the lot, pressure tested it, and got it holding vacuum. Then we put gas back in, started it up, and the aircon was working.
We weren’t done, though. Watching the high side gauge, the pressure just kept climbing. The real cause turned out to be the condenser fan, which wasn’t running. Without that fan pulling air through, the system was getting far too hot, and that heat is what had cooked all those O-rings in the first place.
We sorted the fan, made sure the system had the right amount of gas, checked the temperature, and sent the customer on their way with cold air and a fix that will last.
Replacing the seals without finding what cooked them would have landed the customer right back here in a few months. The why matters.